Loading...
Model: X2EX
Solenoid-operated, rapid advance and feed flow control assembly
Capacity:
Loading...
Model
X2EXLANFA224
Function
Meter In P Normally Closed
Meter In P Normally Open
Technical specifications
This assembly consists of a fixed-orifice, pressure-compensated flow control valve which provides precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at the factory. The rapid or feed rate is selected by a solenoid operated (normally open or closed) 2-way, 2-position valve.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Now available with FLeX Series solenoid valves. See CONFIGURATION section, SOLENOID DESIGNATION to specify.
- Body TypeSandwich
- InterfaceISO 05 - X&Y
- Capacity30 gpm
- Body FeaturesMeter in P
- Control Flow Range0 - 12 gpm
- Seal Plate Included (see notes)
- Stack Height2.49 in.
Model CAD Files
Click the link of the file format you want to download.
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- 990120009 ISO 05 X and Y US sandwich manifold retainer and buna-N seal kit
- 990120010 ISO 05 X and Y US sandwich manifold retainer and Viton seal kit
- 990120011 ISO 05 X and Y Europe sandwich manifold retainer and Viton seal kit
- 990120012 ISO 05 X and Y Europe sandwich manifold retainer and buna-N seal kit
- Stack height value in technical data table includes seal retainer plate.
- This installation requires a seal retainer plate and seal kit which are purchased separately. See "Related Accessories" section.
- For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Highlights
Technical Tips
Technical Information
- PartDescriptionQuantity