Loading...
Loading...

Model

XQCJLANBK

   
   
Control
Adjustment Range
Seal Material
Pilot Ratio (4th Letter) of Primary Cartridge
Port and Material Designation
Model: XQCJ

Accumulator sense, pump unload assembly with flow control valve

Capacity:

Loading...

Model

XQCJLANBK

   
   
Control
Adjustment Range
Seal Material
Pilot Ratio (4th Letter) of Primary Cartridge
Port and Material Designation
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • C, C/S
      Ports P, T, EF: 1/2" NPTF; ACC: 1/2" NPTF; Port G: 1/4" NPTF; Ports D & AUX: 3/8" NPTF; Mtg Holes: .375 - 16UNC x .88 DP;
    • K, K/S
      Ports P, T, EF: SAE 10; ACC: SAE 10; Port G: SAE 4; Ports D & AUX: SAE 6; Mtg Holes: .375 - 16UNC x .88 DP;
    • V, V/S
      Ports P, T, EF: 1/2" BSPP; ACC: 1/2" BSPP; Port G: 1/4" BSPP; Ports D & AUX: 3/8" BSPP; Mtg Holes: M10 x 1.5-6H x .88 DP;

    This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.

    • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
    • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
    • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
    • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
    • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
    • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
    • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
    • Body Type
      Line mount
    • Capacity
      15 gpm
    • Mounting Hole Quantity
      2
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Direct acting or pilot operated - what do I use?
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
    • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
    • Part
      Description
      Quantity
    • A330-006-004*
      SAE Plug
      1
    • A330-006-006*
      SAE Plug
      1
    • A330-006-012*
      SAE Plug
      1
    • Cartridge
      1
    • Cartridge
      1
    • Cartridge - Primary
      1
    • RDDFXBN
      Cartridge
      1

    Keep up with Sun