Loading...
Model: XRGA
Solenoid-operated pilot relief assembly
Capacity:
Loading...
Model
XRGALANFM224
Function
Normally Closed
Normally Open
Technical specifications
Modifiers
Ports
- 4, 4/SPorts 1 & 2: 1" Code 62; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- 4/M, 4/TPorts 1 & 2: 1" Code 62; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
- 5, 5/SPorts 1 & 2: 1-1/4" C62; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- 5/M, 5/TPorts 1 & 2: 1-1/4" C62; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
- D, D/SPorts 1 & 2: 3/4" NPTF; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- E, E/SPorts 1 & 2: 1" NPTF; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- F, F/SPorts 1 & 2: 1 1/4" NPTF; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- L, L/SPorts 1 & 2: SAE 12; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- M, M/SPorts 1 & 2: SAE 16; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- N, N/SPorts 1 & 2: SAE 20; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- P, P/SPorts 1 & 2: 1" Code 61; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- P/M, P/TPorts 1 & 2: 1" Code 61; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
- Q, Q/SPorts 1 & 2: 1 1/4" Code 61 ; Port G: 1/4" NPTF; Mtg Holes: .375 - 16UNC x .62 DP;
- Q/M, Q/TPorts 1 & 2: 1 1/4" Code 61 ; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
- W, W/SPorts 1 & 2: 3/4" BSPP; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
- X, X/SPorts 1 & 2: 1" BSPP; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
- Y, Y/SPorts 1 & 2: 1 1/4" BSPP; Port G: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
This valve assembly provides 2 functions. It relieves from pressure (port 1) to tank (port 2) when pressure at port 1 exceeds the setting of the valve. The solenoid control allows the valve to be vented, dropping the pressure to a minimal level. This assembly is available in both normally open option, normally closed option, as well as an empty pilot control cavity. The normally open option means the pressure is at a low level until the solenoid is energized. The normally closed option means the pressure is at a high level until the solenoid is energized.
- Not suitable for use in load holding applications due to spool leakage.
- Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
- This assembly is well suited to loading and unloading a pump.
- The nature of a vented relief is that it brings the pressure up in a smooth manner. Unloading is abrupt.
- Now available with FLeX Series solenoid valves. See CONFIGURATION section, SOLENOID DESIGNATION to specify.
- Body TypeLine mount
- Capacity60 gpm
- Mounting Hole Quantity2
Model CAD Files
Click the link of the file format you want to download.
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- 1" Code 61 Flange Mounting Hole Data: Inch: 3/8-16 UNC x .88 (22,2 mm) DP, Metric: M10 x 1.5-6H x .88 (22,2 mm) DP
- 1" Code 62 Flange Mounting Hole Data: Inch: 7/16-14 UNC x 1.06 (26,9 mm) DP, Metric: M12 x 1.75-6H x 1.06 (26,9 mm) DP
- 1 1/4" Code 61 Flange Mounting Hole Data: Inch: 7/16-14 UNC x 1.13 (28,6 mm) DP, Metric: M12 x 1.75-6H x 1.13 (28,6 mm) DP
- Flange Mounting Hole Data: Inch: 1/2-13 UNC x 1.00 (25,4 mm) DP, Metric: M14 x 2.0-6H x 1.00 (25,4 mm) DP
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
- For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Highlights
Technical Tips
Technical Information
- PartDescriptionQuantity