Model
YCDCLANA
Model: YCDC
Relief assembly with reverse flow check
Capacity:
Loading...
Model
YCDCLANA
See CAD Files tab below to request images.
Function
Technical specifications
Modifiers
Ports
- A, A/SAll Ports: 1/4" NPTF;
- B, B/SAll Ports: 3/8" NPTF;
- C, C/SAll Ports: 1/2" NPTF;
- I, I/SAll Ports: SAE 6;
- J, J/SAll Ports: SAE 8;
- K, K/SAll Ports: SAE 10;
- T, T/SAll Ports: 1/4" BSPP;
- U, U/SAll Ports: 3/8" BSPP;
- V, V/SAll Ports: 1/2" BSPP;
This assembly consists of a 30 PSI check and a pilot-operated, balanced-piston relief cartridge which is a normally closed pressure regulating valve. When the pressure at the inlet (P port) reaches the valve setting, the valve starts to open to tank (T port), throttling flow to regulate the pressure. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast. This assembly also incorporates an air-bleed and start-up cartridge which is used to purge air trapped in the system to help reduce power requirements and facilitate pump priming during the start-up of blocked center circuits.
- Body TypeLine mount
- Capacity25 gpm
- Mounting Hole Diameter.28 in.
- Mounting Hole DepthThrough
- Mounting Hole Quantity2
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
- For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Highlights
Technical Tips
Technical Information