Can't find the manifold you're looking for? Try our QuickDesign tool!
Loading...
Loading...

Model

YCP

   
   
Modifier
Model: YCP

Cross port with gauge ports

Cavity: T-3A

Loading...

Model

YCP

   
   
Modifier
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • YCP, /10, /11, /S, /S3, /S4
      Ports 1 & 2: 1" Code 61; Gage Ports: 1/4" NPTF;
    • Body Type
      Line mount
    • Cavity
    • Interface
      None
    • Body Features
      Cross port with gauge ports
    • Open Cavities
      2
    • Port Size
      1" Code 61
    • Mounting Hole Thread
      .375-16 UNC - 2B in.
    • Mounting Hole Depth
      .62 in.
    • Mounting Hole Quantity
      2
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.