Loading...
Model: YFEX
Bypass/restrictive, priority flow control with reverse flow check assembly
Capacity:
See CAD Files tab below to request images.
Function
Flow Control, Priority Flow On A, Bypass to T, Reverse Free Flow Check
Technical specifications
This assembly consists of a bypass/restrictive, fixed-orifice, priority flow control which takes an input flow at port A (in) and uses it to satisfy the priority flow at port A (out). If the input flow exceeds the priority flow requirement, the excess is bypassed out port T. The reverse flow check provides unrestricted flow out of port A.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Both priority and bypass flow are usable up to the system operating pressure.
- Bypass flow is not available until priority flow requirements are satisfied.
- Maximum pressure at the priority port should be limited to 3000 psi (210 bar).
- Body TypeSandwich
- InterfaceISO 05 - X&Y
- Capacity30 gpm
- Body FeaturesMeter in A
- Control Flow Range0 - 12 gpm
- Seal Plate Included (see notes)Yes
- Stack Height2.49 in.
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- 990120009 ISO 05 X and Y US sandwich manifold retainer and buna-N seal kit
- 990120010 ISO 05 X and Y US sandwich manifold retainer and Viton seal kit
- 990120011 ISO 05 X and Y Europe sandwich manifold retainer and Viton seal kit
- 990120012 ISO 05 X and Y Europe sandwich manifold retainer and buna-N seal kit
- Stack height value in technical data table includes seal retainer plate.
- This installation requires a seal retainer plate and seal kit which are purchased separately. See "Related Accessories" section.
- For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Highlights