Model

YFEXXANB

Control
Setting Range
Seal Material
Primary Cartridge
Model: YFEX

Bypass/restrictive, priority flow control with reverse flow check assembly

Capacity:

Loading...

Model

YFEXXANB

Control
Setting Range
Seal Material
Primary Cartridge
See CAD Files tab below to request images.
Function
Function image
Flow Control, Priority Flow On A, Bypass to T, Reverse Free Flow Check
Function image
Function image

Technical specifications

This assembly consists of a bypass/restrictive, fixed-orifice, priority flow control which takes an input flow at port A (in) and uses it to satisfy the priority flow at port A (out). If the input flow exceeds the priority flow requirement, the excess is bypassed out port T. The reverse flow check provides unrestricted flow out of port A.

  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
  • Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
  • Both priority and bypass flow are usable up to the system operating pressure.
  • Bypass flow is not available until priority flow requirements are satisfied.
  • Maximum pressure at the priority port should be limited to 3000 psi (210 bar).
  • Body Type
    Sandwich
  • Interface
    ISO 05 - X&Y
  • Capacity
    30 gpm
  • Body Features
    Meter in A
  • Control Flow Range
    0 - 12 gpm
  • Seal Plate Included (see notes)
    Yes
  • Stack Height
    2.49 in.

Model CAD Files

Files not yet avialable. Click below to request them.

  • Why doesn't Sun anodize their aluminum bodies?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • 990120009 ISO 05 X and Y US sandwich manifold retainer and buna-N seal kit
  • 990120010 ISO 05 X and Y US sandwich manifold retainer and Viton seal kit
  • 990120011 ISO 05 X and Y Europe sandwich manifold retainer and Viton seal kit
  • 990120012 ISO 05 X and Y Europe sandwich manifold retainer and buna-N seal kit
  • Stack height value in technical data table includes seal retainer plate.
  • This installation requires a seal retainer plate and seal kit which are purchased separately. See "Related Accessories" section.
  • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.