Model

YFGCLENCA

Control
Maximum Orifice Diameter
Seal Material
Primary Cartridge
Port and Material Designation

Model: YFGC

Rapid advance and feed flow control assembly

Capacity:

Model

YFGCLENCA

Control
Maximum Orifice Diameter
Seal Material
Primary Cartridge
Port and Material Designation
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • A, A/S
      Gage Port (Plugged): 1/4" NPTF;

    This assembly consists of a needle valve which is a fully-adjustable orifice used to regulate flow. It is infinitely adjustable from fully closed up to the maximum orifice diameter. It is not pressure-compensated. It may be used as a flow control or as a shutoff valve. The rapid or feed rate is selected by a vented, pilot-to-open check valve with an external pilot port.

    • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
    • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
    • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
    • Body Type
      Sandwich
    • Interface
      ISO 08
    • Capacity
      60 gpm
    • Body Features
      Meter in A
    • Control Flow Range
      0 - 30 gpm
    • Seal Plate Included (see notes)
    • Stack Height
      3.44 in.

    Model CAD Files

    Files not yet avialable. Click below to request them.

    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Direct acting or pilot operated - what do I use?
    • The external 1/4 NPTF pilot port is part of the pilot to open check cartridge.
    • Seal retainer plate is not required for this assembly.
    • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
    • Part
      Description
      Quantity
    • 340-001*
      Pipe Plug
      1
    • 340-003*
      Pipe Plug
      1
    • 500-001-114*
      O-Ring
      2
    • 500-001-121*
      O-Ring
      4
    • 811-001-002*
      Locating Pin
      1
    • Cartridge
      1
    • Cartridge - Primary
      1