Loading...
Loading...

Model

YPEKLANAK

Control
Adjustment Range
Seal Material
Primary Cartridge
Port and Material Designation
Model: YPEK

Pressure reducing/relieving assembly, with reverse flow check

Capacity:

Loading...

Model

YPEKLANAK

Control
Adjustment Range
Seal Material
Primary Cartridge
Port and Material Designation
See CAD Files tab below to request images.
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • A, A/S
      Ports 1 & 2: 1/4" NPTF; Port 3: 1/4" NPTF; Gage Port: 1/4" NPTF;
    • B, B/S
      Ports 1 & 2: 3/8" NPTF; Port 3: 1/4" NPTF; Gage Port: 1/4" NPTF;
    • C, C/S
      Ports 1 & 2: 1/2" NPTF; Port 3: 1/4" NPTF; Gage Port: 1/4" NPTF;
    • D, D/S
      Ports 1 & 2: 3/4" NPTF; Port 3: 1/4" NPTF; Gage Port: 1/4" NPTF;
    • I, I/S
      Ports 1 & 2: SAE 6; Port 3: SAE 6; Gage Port: 1/4" NPTF;
    • J, J/S
      Ports 1 & 2: SAE 8; Port 3: SAE 6; Gage Port: 1/4" NPTF;
    • K, K/S
      Ports 1 & 2: SAE 10; Port 3: SAE 6; Gage Port: 1/4" NPTF;
    • U, U/S
      Ports 1 & 2: 3/8" BSPP; Port 3: 1/4" BSPP; Gage Port: 1/4" BSPP;
    • V, V/S
      Ports 1 & 2: 1/2" BSPP; Port 3: 1/4" BSPP; Gage Port: 1/4" BSPP;
    • W, W/S
      Ports 1 & 2: 3/4" BSPP; Port 3: 1/4" BSPP; Gage Port: 1/4" BSPP;

    This assembly consists of a pilot-operated pressure reducing/relieving valve which reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). A reverse flow check allows free flow from port 1 to port 2.

    • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
    • Body Type
      Line mount
    • Capacity
      20 gpm
    • Mounting Hole Diameter
      .28 in.
    • Mounting Hole Depth
      Through
    • Mounting Hole Quantity
      2

    Model CAD Files

    Files not yet avialable. Click below to request them.

    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Direct acting or pilot operated - what do I use?
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
    • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.

    Keep up with Sun