Model: YQEA
Sequence assembly, with reverse flow check
Capacity:
Model
YQEALANCK
![Function image](https://cmsimages.sunhydraulics.com/sym-yqea.png)
Technical specifications
- A, A/SPorts 1 & 2: 1/4" NPTF; Port 3: 1/4" NPTF;
- B, B/SPorts 1 & 2: 3/8" NPTF; Port 3: 1/4" NPTF;
- C, C/SPorts 1 & 2: 1/2" NPTF; Port 3: 1/4" NPTF;
- D, D/SPorts 1 & 2: 3/4" NPTF; Port 3: 1/4" NPTF;
- J, J/SPorts 1 & 2: SAE 8; Port 3: SAE 6;
- K, K/SPorts 1 & 2: SAE 10; Port 3: SAE 6;
- U, U/SPorts 1 & 2: 3/8" BSPP; Port 3: 1/4" BSPP;
- V, V/SPorts 1 & 2: 1/2" BSPP; Port 3: 1/4" BSPP;
- W, W/SPorts 1 & 2: 3/4" BSPP; Port 3: 1/4" BSPP;
This assembly consists of a pilot-operated, balanced piston kick-down sequence valve that will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1. Additionally a reverse flow check allows free flow from port 2 to 1.
- Should not be used in load holding applications.
- Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Body TypeLine mount
- Capacity30 gpm
- Mounting Hole Diameter.28 in.
- Mounting Hole DepthThrough
- Mounting Hole Quantity2
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
- For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
- PartDescriptionQuantity