Loading...
Model: YRFF
Fixed-orifice, bypass/restrictive, priority flow control with relief assembly
Capacity:
Loading...
Model
YRFFLAWNNLM
Control
Adjustment Range
Adjustment Range
Seal Material
Seal Material
Control Letter(s) of Subordinate Cartridge
Port and Material Designation
See CAD Files tab below to request images.
Function
Technical specifications
Modifiers
Ports
- D, D/SPorts EF & P: 3/4" NPTF; Ports CF & T: 3/4" NPTF; Gage Port: 1/4" NPTF;
- E, E/SPorts EF & P: 1" NPTF; Ports CF & T: 3/4" NPTF; Gage Port: 1/4" NPTF;
- F, F/SPorts EF & P: 1 1/4" NPTF; Ports CF & T: 3/4" NPTF; Gage Port: 1/4" NPTF;
- L, L/SPorts EF & P: SAE 12; Ports CF & T: SAE 12; Gage Port: 1/4" NPTF;
- M, M/SPorts EF & P: SAE 16; Ports CF & T: SAE 12; Gage Port: 1/4" NPTF;
- N, N/SPorts EF & P: SAE 20; Ports CF & T: SAE 12; Gage Port: 1/4" NPTF;
- P, P/SPorts EF & P: 1" Code 61; Ports CF & T: 1" Code 61; Gage Port: 1/4" NPTF;
- P/M, P/TPorts EF & P: 1" Code 61; Ports CF & T: 1" Code 61; Gage Port: 1/4" BSPP;
- Q, Q/SPorts EF & P: 1 1/4" Code 61 ; Ports CF & T: 1" Code 61; Gage Port: 1/4" NPTF;
- Q/M, Q/TPorts EF & P: 1 1/4" Code 61 ; Ports CF & T: 1" Code 61; Gage Port: 1/4" BSPP;
- W, W/SPorts EF & P: 3/4" BSPP; Ports CF & T: 3/4" BSPP; Gage Port: 1/4" BSPP;
- X, X/SPorts EF & P: 1" BSPP; Ports CF & T: 3/4" BSPP; Gage Port: 1/4" BSPP;
- Y, Y/SPorts EF & P: 1 1/4" BSPP; Ports CF & T: 3/4" BSPP; Gage Port: 1/4" BSPP;
This assembly consists of a bypass/restrictive, fixed-orifice, priority flow control which takes an input flow at port P and uses it to satisfy the priority flow at port CF. If the input flow exceeds the priority flow requirement, the excess is bypassed out port EF. The bypass flow may be used in a secondary circuit. The relief valve protects the controlled flow from over-pressurization, relieving excess flow out of port T.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
- Pressure at the bypass port (port EF) may exceed pressure at the priority port (port CF).
- Maximum pressure at the priority port should be limited to 3000 psi (210 bar).
- Bypass flow is not available until priority flow requirements are satisfied.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- Body TypeLine mount
- Capacity60 gpm
- Control Flow Range.2 - 50 gpm
- Mounting Hole Diameter.41 in.
- Mounting Hole DepthThrough
- Mounting Hole Quantity2
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
- For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Highlights
Technical Tips
Technical Information