Model

CBBGXMNV

Fixed Pressure Range
Seal Material
Material/Coating

Fixed setting, 4.5:1 pilot ratio, restrictive counterbalance valve

Cavity: T-11A | Capacity:

Loading...

Model

CBBGXMNV

Fixed Pressure Range
Seal Material
Material/Coating
See CAD Files tab below to request images.

Technical specifications

Fixed-setting, 3-port counterbalance valves with pilot-assist function similarly to the adjustable versions except the fixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Restrictive valves have no relief capacity other than as a thermal relief.
  • The maximum recommended load pressure for the M range is 3600 psi (250 bar). The highest cracking pressure for the M range will be less than 5600 psi (390 bar).
  • The maximum recommended load pressure for the V range is 2450 psi (170 bar). The highest cracking pressure for the V range will be less than 3800 psi (260 bar).
  • The maximum recommended load pressure for the X range is 2700 psi (190 bar). The highest cracking pressure for the X range will be less than 4200 psi (290 bar).
  • The maximum recommended load pressure for the Z range is 3170 psi (220 bar). The highest cracking pressure for the Z range will be less than 4900 psi (340 bar).
  • Note: The pressures listed under RANGE are approximate, mean values and should not be used for inspection purposes.
  • Note: The percentage difference between the cracking and reseat values for the fixed and adjustable versions of this valve are identical. However, the cracking point for the adjustable control can be set via the adjustment mechanism to within +/- 50 psi (3,5 bar) of the specified value. In the case of the fixed-setting version, the setting tolerance can only be maintained within a several hundred psi span, depending on the range. The maximum recommended load pressure for any given range is the minimum possible setting divided by 1.3.
  • Fixed-setting counterbalance valves offer a shorter cartridge extension than the adjustable version.
  • Fixed-setting counterbalance valves can be used to protect cylinder seals in outrigger circuits from damage due to thermal expansion, however, they probably should not be applied in circuits in which a matched valve setting may be required such as dual cylinder applications.
  • This valve has positive seals between all ports.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    5 gpm
  • Pilot Ratio
    4.5:1
  • Maximum Recommended Load Pressure
    See Technical Features
  • Check Cracking Pressure
    25 psi
  • Factory Pressure Settings Established at
    2 in³/min.
  • Maximum Valve Leakage at Reseat
    5 drops/min.
  • Operating Characteristic
    Restrictive
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Model Weight
    .35 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • Why is turning the adjust screw for counterbalance valves opposite of most other valves?
  • What parts of the Sun cartridge valve are field serviceable?
  • You say your valves leak 5 drops/min. How can I keep my load from drifting?
  • How do I determine the setting of a counterbalance valve?
  • How do I know how much pilot pressure is required to lower a load with a counterbalance valve?
  • When should I use a vented counterbalance valve?
  • How does Sun test a counterbalance valve for leakage?  
  • How do I decide which pilot ratio to select?
  • How big is a drop of hydraulic oil?  
  • Why can't I use a counterbalance valve in a closed loop transmission circuit?  
  • What do you mean by the setting of a counterbalance valve and what should it be?
  • I don't need pilot assist. Can I just block port 3?
  • Can I use an atmospherically vented counterbalance valve instead of the four-port version to save on plumbing?
  • Why is it that your valves have pilot ratios below 10:1, while other manufacturers start at 7:1 and go up?
  • Why can't I block the pilot vent port? That area is positively sealed, isn't it?  
  • Should I replace the counterbalance valve if my cylinder is drifting or moving?
  • I have a pilot-to-open check on a large cylinder and the decompression is violent. Can I use a counterbalance instead?
  • How do I size a counterbalance valve?
  • Can I adjust a counterbalance valve in the field?
  • Why do you offer 2 check valve cracking pressures?
  • What happens to the counterbalance valve if I have backpressure in my system?
  • What do you mean by hysteresis when referring to a counterbalance valve?

Keep up with Sun