Vented pilot-to-open check valve with external pilot port, sealed pilot, and stem seal
Cavity: T-2A | Capacity:
Technical specifications
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the vent (port 3).
- There is a positve seal between ports 2 and 3.
- These valves should be considered service items only. New applications should use valves from the CV*V family.
- Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
- Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
- Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
- This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different pilot/vent configuration.
- This valve is a direct replacement for the CK*E, CK*F, CKEG, and CK*H and uses components from the new vented design. It does not have the proportional pressure reducing characteristic. Note: Replacing the older design with this valve can result in a 33% increase in pressure at the actuator.
- Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
- Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
- Sealed pilot for use in circuits where cross port leakage is undesirable.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity30 gpm
- Maximum Operating Pressure5000 psi
- Pilot Ratio3:1
- Maximum Valve Leakage at 110 SUS (24 cSt)1 drops/min.
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Model Weight.50 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
What should I do if I need load holding on the rod of a high ratio cylinder?
What happens to the pilot-to-open check valve if I have back pressure in my system?
Other companies make high ratio PO checks. Why doesn't Sun?
Can I control the motion of a load with a pilot-to-open check valve?
How do I know how much pilot pressure is required to open a pilot-to-open check valve?
Where should I mount pilot-to-open check valves in my system?
Can I use pilot-to-open check valves with paired cylinders?
What about intensification?
How big is a drop of hydraulic oil?
Vented pilot-to-open check valves are insensitive to pressure on the valve port (port 2), aren't they?
Should I replace the pilot-to-open check valve if my cylinder is drifting or moving?
Where should a vented valve be vented?
What is the actual pilot ratio of Sun's pilot to open check valves?
What ever happened to the Delrin seated valves?
What does pilot ratio refer to in a pilot-to-open check valve?
Direct acting or pilot operated - what do I use?
What is the difference between pilot-to-open check valves with sealed pilots compared to standard bleed through versions?
My load keeps drifting, and every time I take your valves out, the nose seals have been blown out of their grooves.
I want to use your pilot-to-open checks on air. Will they work?
Can I use a three-port vented pilot-to-open check valve instead of the four-port version to save on plumbing?