Loading...
Single ball shuttle valve with signal at port 2
Cavity: T-11A | Capacity:
Technical specifications
The single ball shuttle connects the higher of two work ports to the signal or common port. The signal is sensed at port 2.
- Shuttle cartridges feature hardened steel balls and seats for excellent wear characteristics and contamination tolerance.
- The single ball allows for the decay of the pressure signal when both load ports drop to a lower pressure.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity2.5 gpm
- Maximum Operating Pressure5000 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)5 drops/min.
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight.20 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- 3BC Cushion lock with shuttle
- 3BD Cushion lock with shuttle
- 3BK Cushion lock with shuttle
- 3BL Cushion lock with shuttle
- 3BV Cushion lock with shuttle
- 3BW Cushion lock with shuttle
- 5BC Cushion lock with make up checks and shuttle
- 5BD Cushion lock with make up checks and shuttle
- 5BK Cushion lock with make up checks and shuttle
- 5BL Cushion lock with make up checks and shuttle
- 5BV Cushion lock with make up checks and shuttle
- 5BW Cushion lock with make up checks and shuttle
- HG5 Ninety degree with shuttle
- HNE Cushion lock with shuttle
- HNF Cushion lock with shuttle
- HNM Cushion lock with shuttle
- HNN Cushion lock with shuttle
- HNX Cushion lock with shuttle
- HNY Cushion lock with shuttle
- HQE Cushion lock with make up checks and shuttle
- HQF Cushion lock with make up checks and shuttle
- HQM Cushion lock with make up checks and shuttle
- HQN Cushion lock with make up checks and shuttle
- HQX Cushion lock with make up checks and shuttle
- HQY Cushion lock with make up checks and shuttle
- XYR Eaton/Char-Lynn 2000: Cross pilot with shuttle
- XYS Eaton/Char-Lynn 2000: Cross pilot with shuttle
- XYT Eaton/Char-Lynn 2000: Cross pilot with shuttle