Model: XYS

Eaton/Char-Lynn 2000: Cross pilot with shuttle

Cavity: T-2A

Loading...

Model

XYS

   
   
Modifier
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • XYS, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4
      Ports VA & VB: SAE 12; Port S: SAE 4;
    • Body Type
      Motor mount
    • Cavity
    • Interface
      Eaton/Char-Lynn 2000
    • Body Features
      Cross pilot with shuttle
    • Open Cavities
      2
    • Port Size
      SAE 12
    • Mounting Hole Diameter
      .41 in.
    • Mounting Hole Depth
      Through
    • Mounting Hole C'bore Diameter
      .59 in.
    • Mounting Hole C'bore Depth
      .38 in.
    • Mounting Hole Quantity
      3
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.