Normally open, balanced poppet, logic element - vent-to-close
Cavity: T-22A | Capacity:
Technical specifications
This is a normally open, balanced poppet, switching element. When the vent port (port 4) is blocked, the poppet remains in the open position. Venting port 4 shifts it to the closed position, provided there is sufficient pressure at port 3.
- Unique balanced construction provides predictable switching with 5000 psi (350 bar) at both ports 1 and 2, with the vent (port 4) open and a minimum pilot pressure of 400 psi (30 bar) at port 3.
- Valve will open when the pilot pressure falls below 145 psi (10 bar).
- These valves are hydraulically balanced between port 1 and port 2.
- Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
- Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
- Port 4 may be externally connected to a pilot switching valve. The pilot valve should have a leakage rate of less than 10 drops/min. and be able to satisfy the pilot flow requirements. Sun model DAA*-*** solenoid pilot valve is ideal for this application.
- All ports will accept 5000 psi (350 bar).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity30 gpm
- Maximum Operating Pressure5000 psi
- Minimum Pilot Pressure Required to Shift Valve300 psi
- Control Pilot FlowSee Performance Data
- Maximum Valve Leakage at 110 SUS (24 cSt)10 drops/min.@5000 psi
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Model Weight.65 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- DOFR8 Normally open, balanced poppet, logic element with integral T-8A control cavity - vent-to-close
Highlights
Technical Tips
Technical Information