Loading...
Loading...

Model

990022006

Model: 990022006

Series 2 - T-22A cavity, Viton, cartridge seal kit

Cavity: T-22A

Loading...

Model

990022006

See CAD Files tab below to request images.

Technical specifications

Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

  • The shelf life for this cartridge seal kit is twenty years from date of purchase. This date will be printed on the kit packaging.
  • Cavity
  • Series
  • Cartridge Thread
    1"-14 UNS
  • Valve Hex Size
    1 1/8 in.
  • Valve Installation Torque
    45 - 50 lbf ft

What models can this kit be used with?

  • CVEV Vented pilot-to-open check valve
  • CWEA 3:1 pilot ratio, vented counterbalance valve
  • CWEG 5:1 pilot ratio, vented counterbalance valve
  • CWEK 1:1 pilot ratio, vented counterbalance valve
  • CWEL 2:1 pilot ratio, vented counterbalance valve
  • DKFP Normally closed, balanced poppet, logic element - pressure adjustable
  • DKFR Normally closed, balanced poppet, logic element - vent-to-open
  • DKFR8 Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open
  • DKFS Normally closed, balanced poppet, logic element - pilot-to-open
  • DOFP Normally open, balanced poppet, logic element - pressure adjustable
  • DOFR Normally open, balanced poppet, logic element - vent-to-close
  • DOFR8 Normally open, balanced poppet, logic element with integral T-8A control cavity - vent-to-close
  • DOFS Normally open, balanced poppet, logic element - pilot-to-close
  • DPCM 2-way, pilot-operated, directional valve with drain to port 4 - normally open
  • DPCN 2-way, pilot-operated, directional valve with drain to port 4 - normally closed
  • DPCO 3-way, pilot-operated, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
  • DPCP 3-way, pilot-operated, directional valve with drain to port 4 (1 to 2 open, 3 blocked)
  • DRCO 3-way, direct-acting, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
  • DRCR 3-way, direct-acting, directional valve with drain to port 4 (3 to 4 open, port 2 blocked)
  • DVCM 2-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity - normally open
  • DVCN 2-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity - normally closed
  • DVCO 3-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity (1 blocked, 2 to 3 open)
  • DVCP 3-way, vent-to-operate, directional valve with drain to port 4 and integral T-8A control cavity (1 to 2 open, 3 blocked)
  • FKDA 2-way, pilot-shifted, proportional throttle
  • FKDB 2-way, pilot-shifted, proportional throttle with bleed down
  • FKEA 2-way, pilot-shifted, proportional throttle, high capacity
  • FKEB 2-way, pilot-shifted, proportional throttle with bleed down, high capacity
  • FVDA Ventable, fixed-orifice, bypass/restrictive, priority flow control valve
  • FVDA8 Ventable, fixed-orifice, bypass/restrictive, priority flow control valve with integral T-8A control cavity
  • MWEA Vented, 3:1 pilot ratio, load reactive, load control valve
  • MWEAX Fixed setting, vented, 3:1 pilot ratio, load reactive, load control valve
  • MWEB Vented, 1.5:1 pilot ratio, load reactive, load control valve
  • MWEG Vented, 4.5:1 pilot ratio, load reactive, load control valve
  • MWEGX Fixed setting, vented, 4.5:1 pilot ratio, load reactive, load control valve
  • MWEM Vented, balanced, load control valve
  • MWEP Vented LoadMatch™ counterbalance valve
  • PSFB Direct-acting, pressure reducing/relieving valve with drain to port 4
  • PSFT Direct-acting, pressure reducing/relieving main stage piloted from port 4
  • PVFA Pilot-operated, pressure reducing/relieving valve with drain to port 4
  • PVFA8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity and drain to port 4
  • PVFB Ventable, pilot-operated, pressure reducing/relieving valve
  • PVFD Ventable, pilot-operated, pressure reducing/relieving valve with drilled piston orifice
  • RVED Ventable, pilot-operated, balanced piston relief valve with drain to port 4
  • RVED8 Ventable, pilot-operated, balanced piston relief main stage with integral T-8A control cavity and drain to port 4
  • XNCA All ports blocked cavity plug
  • XNOA Ports 3 and 4 or port 5 and 6 blocked, all other ports open cavity plug
  • Install back-up rings and O-rings as shown in views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.
  • Part
    Description
    Quantity
    View
  • 500-101-018
    O-Ring
    1
    D
  • 500-101-021
    O-Ring
    2
    A,B
  • 500-102-020
    O-Ring
    1
    C
  • 515-102-018
    Backup Ring
    2
    D
  • 515-102-020
    Backup Ring
    1
    C
  • 515-102-021
    Backup Ring
    3
    A,B

Keep up with Sun