Model: DOHD

Normally open, balanced poppet, logic element - vent-to-close

Cavity: T-17A | Capacity:

Model

DOHDEHN

Control
Minimum Pilot Pressure
Seal Material

Technical specifications

This is a normally open, balanced poppet, switching element. When the external vent port is blocked, the poppet remains in the open position. Venting the external port shifts it to the closed position, provided there is sufficient pressure at port 3.

  • Unique balanced construction provides predictable switching with 5000 psi (350 bar) at port 1 and port 2, with the external drain port open and a minimum pilot pressure of 300 psi (20 bar).
  • Valve will open when the pilot pressure falls below 145 psi (10 bar).
  • The external -4 SAE vent port may be directly connected to a pilot switching valve. The pilot valve should have a leakage rate of less than 10 drops/min (0,7 cc/min). and be able to satisfy the pilot flow requirements. Sun model DAA*-*** solenoid pilot valve is ideal for this application.
  • These valves are hydraulically balanced between port 1 and port 2.
  • Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
  • Port 1 and port 2 are fully sealed from port 3.
  • All ports will accept 5000 psi (350 bar).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    60 gpm
  • Maximum Operating Pressure
    5000 psi
  • Minimum Pilot Pressure Required to Shift Valve
    300 psi
  • Control Pilot Flow
    See Performance Data
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    10 drops/min.@5000 psi
  • Pilot Volume Displacement
    .05 in³
  • Valve Hex Size
    1 1/4 in.
  • Valve Installation Torque
    150 - 160 lbf ft
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge