Loading...
Loading...

Model

990017006

Model: 990017006

Series 3 - T-17A cavity, Viton, cartridge seal kit

Cavity: T-17A

Loading...

Model

990017006

See CAD Files tab below to request images.

Technical specifications

  • The shelf life for this cartridge seal kit is twenty years from date of purchase. This date will be printed on the kit packaging.
  • Cavity
  • Series
  • Cartridge Thread
    1"-14 UNS
  • Valve Hex Size
    1 1/4 in.
  • Valve Installation Torque
    150 - 160 lbf ft

What models can this kit be used with?

  • CBFA 3:1 pilot ratio, restrictive counterbalance valve
  • CBFB 1.5:1 pilot ratio, semi-restrictive counterbalance valve
  • CBFC 3:1 pilot ratio, semi-restrictive counterbalance valve
  • CBFD 4.5:1 pilot ratio, semi-restrictive counterbalance valve
  • CBFG 4.5:1 pilot ratio, restrictive counterbalance valve
  • CBFL 2.3:1 pilot ratio, semi-restrictive counterbalance valve
  • CBGA 3:1 pilot ratio, standard capacity counterbalance valve
  • CBGB 1.5:1 pilot ratio, standard capacity counterbalance valve
  • CBGG 4.5:1 pilot ratio, standard capacity counterbalance valve
  • CBGH 10:1 pilot ratio, standard capacity counterbalance valve
  • CBGL 2.3:1 pilot ratio, standard capacity counterbalance valve
  • CBGY 2:1 pilot ratio, standard capacity counterbalance valve
  • CKGB Pilot-to-open check valve with standard pilot
  • CKGD Pilot-to-open check valve with sealed pilot
  • CKGV Vented pilot-to-open check valve - atmospherically referenced
  • CNGD Free flow side to nose check valve with bypass orifice and port 3 blocked
  • CNGE Pilot-to-open check valve with bypass orifice
  • CNHE Pilot-to-close check valve with bypass orifice
  • COHA Pilot-to-close check valve
  • CXGE Free flow side to nose check valve with port 3 blocked
  • CXHC Free flow nose to side check valve with port 3 blocked
  • DKHC Normally closed, balanced poppet, logic element - pilot-to-open
  • DKHD Normally closed, balanced poppet, logic element - vent-to-open
  • DOHC Normally open, balanced poppet, logic element - pilot-to-close
  • DOHD Normally open, balanced poppet, logic element - vent-to-close
  • FREA Fixed-orifice, bypass/restrictive, priority, flow control valve
  • FREP FLeX Series 3-way, direct-acting, electro-proportional, bypass/restrictive, priority flow control valve
  • LKHC Pilot-to-open, spring-biased closed, unbalanced poppet logic element
  • LKHCZ Pilot-to-open, spring-biased closed, unbalanced poppet logic element with position switch
  • LOGCZ Pilot-to-close, spring-biased closed, unbalanced poppet logic element with metering notches and position switch
  • LOHA Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1
  • LOHA8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 and integral T-8A control cavity
  • LOHB Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 2
  • LOHB8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 2 and integral T-8A control cavity
  • LOHC Pilot-to-close, spring-biased closed, unbalanced poppet logic element
  • LOHCL Pilot-to-close, spring-biased closed, unbalanced poppet logic element
  • LOHCZ Pilot-to-close, spring-biased closed, unbalanced poppet logic element with position switch
  • LOHD Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2
  • LOHD8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2 and integral T-8A control cavity
  • LOHO Pilot-to-close, spring-biased open, unbalanced poppet logic element
  • LPHA Normally open, modulating element with pilot source from port 1
  • LPHC Normally open, modulating element
  • LRHA Normally closed, modulating element with pilot source from port 1
  • LRHC Normally closed, modulating element
  • MBGA 3:1 pilot ratio, load reactive, load control valve
  • MBGAX Fixed setting, 3:1 pilot ratio, load reactive, load control valve
  • MBGB 1.5:1 pilot ratio, load reactive, load control valve
  • MBGBX Fixed setting, 1.5:1 pilot ratio, load reactive, load control valve
  • MBGG 4.5:1 pilot ratio, load reactive, load control valve
  • MBGM Balanced, load control valve
  • PBHB Pilot-operated, pressure reducing valve
  • PBHB8 Pilot-operated, pressure reducing main stage with integral T-8A control cavity
  • PBHC Air-controlled, pilot-operated, pressure reducing valve
  • PBHF Pilot-operated, pressure reducing valve with drilled piston orifice
  • PBHF8 Pilot-operated, pressure reducing main stage with drilled piston orifice and integral T-8A control cavity
  • PPHB Pilot-operated, pressure reducing/relieving valve
  • PPHB8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity
  • PPHC Air-controlled, pilot-operated, pressure reducing/relieving valve
  • PPHF Pilot-operated, pressure reducing/relieving valve with drilled piston orifice
  • PPHF8 Pilot-operated, pressure reducing/relieving main stage with drilled piston orifice and integral T-8A control cavity
  • PRHB Direct-acting, pressure reducing/relieving valve
  • PRHR Direct-acting, pressure reducing valve
  • RSHC Pilot-operated, balanced piston sequence valve
  • RSHC8 Pilot-operated, balanced piston sequence main stage with integral T-8A control cavity
  • RSHE Air-controlled, pilot-operated, balanced piston sequence valve
  • RVGA Ventable, pilot-operated, balanced piston relief valve
  • RVGB Normally closed modulating element valve with relief function
  • SCGA Direct-acting sequence valve with reverse flow check
  • SQHB Kick-down, pilot-operated, balanced piston sequence valve
  • XHBA Port 1 to 3 open, port 2 blocked cavity plug
  • XHCA All ports blocked cavity plug
  • XHOA Port 1 to 2 open, port 3 blocked cavity plug
  • XHOAE Ports 1 and 2 to external port, port 3 blocked cavity plug
  • XHOB All ports open cavity plug
  • XHOC T-17A cavity to T-11A cavity converter
  • LOHDL Pilot-to-close, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2
  • Install back-up rings and O-rings as shown in views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.
  • Part
    Description
    Quantity
    View
  • 500-101-120
    O-Ring
    1
    C
  • 500-101-126
    O-Ring
    1
    A
  • 500-102-124
    O-Ring
    1
    B
  • 515-102-121
    Backup Ring
    2
    C
  • 515-102-123
    Backup Ring
    1
    B
  • 515-102-126
    Backup Ring
    1
    A

Keep up with Sun