Loading...
3-way, pilot-operated, directional valve with drain to port 4 (1 to 2 open, 3 blocked)
Cavity: T-22A | Capacity:
Technical specifications
Pilot-operated, 3-way directional cartridges (1 to 2 open, 3 blocked) are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
- Port 4 can be blocked to prevent the valve from shifting.
- Port 3 can be used as a work port.
- Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
- Pressure at port 4 is directly additive to the setting of the valve.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
- When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve setting. If this is a problem, the direct acting version of this valve would be a solution.
- Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity15 gpm
- Maximum Operating Pressure5000 psi
- Control Pilot Flow10 - 15 in³/min.
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)1 in³/min.@1000 psi
- Adjustment - No. of CW Turns from Min. to Max. setting5
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.60 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Where would I use a DR__ instead of a DP__?
I used a DP** in a circuit but it hangs. What happened?
Direct acting or pilot operated - what do I use?
Highlights
Technical Tips
Technical Information