FLeX Series pilot-operated, normally closed, electro-proportional throttle - flow 2-1
Cavity: T-162A | Capacity:
Technical specifications
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally, allowing flow from port 2 to 1. In the open condition, flow from 1 to 2 will cause the valve to auto-close and only pilot flow will pass from 1 to 2.
- Capacities rated at 200 psi (14 bar) differential and maximum rated coil current.
- FLeX Series proportional valves are fully compatible with the XMD Expandable Mobile Drivers from Sun.
- Designed and tested to 10 million on-off operational cycles.
- Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
- Improved linearity and resolution over similar competing valves.
- Designed using CFD fluid simulation for optimized geometries.
- For optimum performance, an amplifier with current feedback and adjustable dither (100 - 250 Hz) should be used.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using an FPB* with an external compensator.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- This valve can be used with both the 740 Series high-power coils and 747 Series hazardous location coils.
- A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- A FULL DATA SHEET is available for this model using the link at the top of the page.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity5 gpm
- Maximum Operating Pressure5000 psi
- Hysteresis (with dither)15%
- Linearity (with dither)3%
- Repeatability (with dither)3%
- Recommended dither frequency140 Hz
- Check Cracking Pressure100 psi
- Deadband, nominal (as a percentage of input)48%
- Maximum Valve Leakage at 110 SUS (24 cSt)0.004 in³/min.@3000 psi
- Viscosity Range35 - 2000 SUS
- Response Time - Typical50 ms
- Switching Frequency15,000 max. cycles/hr
- Valve Hex Size3/4 in.
- Valve Installation Torque20 - 25 lbf ft
- Model Weight5.6 oz.
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
Can FLeX proportional valves be driven with an explosion proof coil?
What is the difference between nominal and maximum flow capacity?
Do FLeX valves utilize a floating nose design?
Is the FLeX program available in QuickDesign SmartConnect?
What happens if I block the control flow (priority) port?
I have a heat problem, will Sun's priority flow control help?
How big is a drop of hydraulic oil?
What is the pressure drop through a flow control?
What is the compensating pressure of Sun's flow controls?
How accurate are Sun's flow controls?
What happens if I block the bypass port on a priority flow control?
- Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
- An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Highlights
Technical Tips
Technical Information