Loading...
Loading...

Modelo

FPBFXDN

Control
Flow Rate
Seal Material
bobina

FLeX Series pilot-operated, normalmente cerrado, electro-proporcional estrangulación - caudal 2-1

Cavity: T-162A | Capacity:

Loading...

Modelo

FPBFXDN

Control
Flow Rate
Seal Material
bobina

Especificaciones técnicas

  • cavidad
    T-162A
  • Series
  • Capacity
    5 gpm
  • Maximum Operating Pressure
    5000 psi
  • Hysteresis (with dither)
    15%
  • Linearity (with dither)
    3%
  • Repeatability (with dither)
    3%
  • Recommended dither frequency
    140 Hz
  • Check Cracking Pressure
    100 psi
  • Deadband, nominal (as a percentage of input)
    48%
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    0.004 in³/min.@3000 psi
  • Viscosity Range
    35 - 2000 SUS
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Valve Hex Size
    3/4 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Model Weight
    5.6 oz.
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • Can FLeX proportional valves be driven with an explosion proof coil?
  • What is the difference between nominal and maximum flow capacity?
  • Do FLeX valves utilize a floating nose design?
  • Is the FLeX program available in QuickDesign SmartConnect?
  • What happens if I block the control flow (priority) port?
  • I have a heat problem, will Sun's priority flow control help?
  • How big is a drop of hydraulic oil?  
  • What is the pressure drop through a flow control?
  • What is the compensating pressure of Sun's flow controls?
  • How accurate are Sun's flow controls?
  • What happens if I block the bypass port on a priority flow control?
Highlights
Consejos técnicos
Información técnica

Keep up with Sun