FLeX Series pilot-operated, normally closed, electro-proportional throttle with reverse flow check - flow 2-1

Cavity: T-162A | Capacity:

Loading...

Model

FPBGXDN

Control
Flow Rate
Seal Material
Coil

Technical specifications

This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally, allowing flow from port 2 to 1. The check will allow flow from 1 to 2 in either the open or closed condition.

  • Capacities rated at 200 psi (14 bar) differential and maximum rated coil current.
  • FLeX Series proportional valves are fully compatible with the XMD Expandable Mobile Drivers from Sun.
  • Designed and tested to 10 million on-off operational cycles.
  • Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
  • Improved linearity and resolution over similar competing valves.
  • Designed using CFD fluid simulation for optimized geometries.
  • For optimum performance, an amplifier with current feedback and adjustable dither (100 - 250 Hz) should be used.
  • Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using an FPB* with an external compensator.
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • This valve can be used with both the 740 Series high-power coils and 747 Series hazardous location coils.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • A FULL DATA SHEET is available for this model using the link at the top of the page.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    5 gpm
  • Maximum Operating Pressure
    5000 psi
  • Hysteresis (with dither)
    15%
  • Linearity (with dither)
    3%
  • Repeatability (with dither)
    3%
  • Recommended dither frequency
    140 Hz
  • Check Cracking Pressure
    100 psi
  • Deadband, nominal (as a percentage of input)
    48%
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    0.004 in³/min.@5000 psi
  • Viscosity Range
    35 - 2000 SUS
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Valve Hex Size
    3/4 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Model Weight
    .35 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • Does this FLeX series throttle control flow bidirectionally?
  • Can FLeX proportional valves be driven with an explosion proof coil?
  • What is the difference between nominal and maximum flow capacity?
  • Do FLeX valves utilize a floating nose design?
  • Is the FLeX program available in QuickDesign SmartConnect?
  • What happens if I block the control flow (priority) port?
  • I have a heat problem, will Sun's priority flow control help?
  • How big is a drop of hydraulic oil?  
  • What is the pressure drop through a flow control?
  • What is the compensating pressure of Sun's flow controls?
  • How accurate are Sun's flow controls?