Loading...
FLeX Series pilot-operated, normalmente cerrado, electro-proporcional estrangulación con anti-retorno de caudal inverso - caudal 2-1
Cavity: T-162A | Capacity:
Especificaciones técnicas
- cavidadT-162A
- Series
- Capacity5 gpm
- Maximum Operating Pressure5000 psi
- Hysteresis (with dither)15%
- Linearity (with dither)3%
- Repeatability (with dither)3%
- Recommended dither frequency140 Hz
- Check Cracking Pressure100 psi
- Deadband, nominal (as a percentage of input)48%
- Maximum Valve Leakage at 110 SUS (24 cSt)0.004 in³/min.@5000 psi
- Viscosity Range35 - 2000 SUS
- Response Time - Typical50 ms
- Switching Frequency15,000 max. cycles/hr
- Valve Hex Size3/4 in.
- Valve Installation Torque20 - 25 lbf ft
- Model Weight.35 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
Does this FLeX series throttle control flow bidirectionally?
Can FLeX proportional valves be driven with an explosion proof coil?
What is the difference between nominal and maximum flow capacity?
Do FLeX valves utilize a floating nose design?
Is the FLeX program available in QuickDesign SmartConnect?
What happens if I block the control flow (priority) port?
I have a heat problem, will Sun's priority flow control help?
How big is a drop of hydraulic oil?
What is the pressure drop through a flow control?
What is the compensating pressure of Sun's flow controls?
How accurate are Sun's flow controls?
Highlights
Consejos técnicos