Fixed-orifice, flow fuse valve

Cavity: T-13A | Capacity:

Loading...

Model

FQCAXAN

Control
Setting Range
Seal Material
Material/Coating

Technical specifications

Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break. The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve setting.

  • Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
  • Valve closes when flow from port 1 to port 2 exceeds the setting of the valve. Valve resets when pressures at port 1 and port 2 are equal.
  • Flow setting should be at least 25% above maximum normal system flow. Customer must specify flow when ordering valve.
  • These are spool type valves, therefore there is leakage. Some actuator drift may occur.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Can I use a flow fuse to provide fire protection?
  • Every time I try to lower my load the flow fuse trips. What's wrong?
  • How should I choose the setting of a flow fuse?
  • Can I use a flow fuse to prevent the loss of oil?