Loading...
Fixed-orifice, flow fuse valve
Cavity: T-13A | Capacity:
Technical specifications
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break. The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve setting.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Valve closes when flow from port 1 to port 2 exceeds the setting of the valve. Valve resets when pressures at port 1 and port 2 are equal.
- Flow setting should be at least 25% above maximum normal system flow. Customer must specify flow when ordering valve.
- These are spool type valves, therefore there is leakage. Some actuator drift may occur.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity6 gpm
- Maximum Operating Pressure5000 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight.20 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Can I use a flow fuse to provide fire protection?
Every time I try to lower my load the flow fuse trips. What's wrong?
How should I choose the setting of a flow fuse?
Can I use a flow fuse to prevent the loss of oil?
Highlights
Technical Tips
Technical Information