Modelo

FQCAXAN

Control
Setting Range
Seal Material
Material/Coating

Model: FQCA

Fixed-orifice, fusible de caudal válvula

Cavity: T-13A | Capacity:

Modelo

FQCAXAN

Control
Setting Range
Seal Material
Material/Coating

Especificaciones técnicas

  • cavidad
    T-13A
  • Series
  • Capacity
    6 gpm
  • Maximum Operating Pressure
    5000 psi
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    2 in³/min.@1000 psi
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Model Weight
    .20 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Can I use a flow fuse to provide fire protection?
  • Every time I try to lower my load the flow fuse trips. What's wrong?
  • How should I choose the setting of a flow fuse?
  • Can I use a flow fuse to prevent the loss of oil?