Model

FVCA8AN

Setting Range
Seal Material

Ventable, fixed-orifice, bypass/restrictive, priority flow control valve with integral T-8A control cavity

Cavity: T-21A | Capacity:

Loading...

Model

FVCA8AN

Setting Range
Seal Material

Technical specifications

This valve is a ventable, bypass/restrictive, fixed-orifice, priority flow control with an integral pilot control cavity. The pilot control cavity will accept any T-8A pilot pressure or directional control cartridge. It takes an input flow at port 1 and uses it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess flow is bypassed out of port 2. Bypass flow may be used for a secondary circuit. Depending on which pilot control valve is installed in the T-8A cavity, priority flow can be selected electrically, manually, hydraulically or pneumatically.

  • Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
  • Using a pressure control in the T-8A pilot control cavity will limit the pressure at the priority port (port 3). If pressure on the bypass port (port 2) exceeds the setting of the pressure control, priority flow will be shut off and all the flow will go out the bypass port.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value.
  • Both priority and bypass flow are usable up to the system operating pressure.
  • Priority remains relatively constant regardless of variation in input flow.
  • Bypass flow is not available until priority flow requirements are satisfied, except when the valve is vented. When port 4 (vent) is open, all flow diverts to port 2 if pressure at port 1 (inlet) is 150 psi (10,5 bar) or higher.
  • Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • The -8 control option allows the pilot control valve to be incorporated directly into the end of the cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    6 gpm
  • Maximum Operating Pressure
    5000 psi
  • Maximum Input Flow
    15 gpm
  • Nominal Vent Flow
    46 in³/min.
  • Pilot Control Cavity
    T-8A
  • Pilot Control Valve Hex Size
    7/8 in.
  • Pilot Control Valve Installation Torque
    20 - 25 lbf ft
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Model Weight
    .30 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.