Air-controlled, pilot-operated, pressure reducing/relieving valve
Cavity: T-17A | Capacity:
Technical specifications
Air-controlled, pilot-operated pressure reducing/relieving valves use compressed air over a diaphragm instead of an adjustable spring to control the setting. These valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The air signal is supplied through a port in the hex-end of the cartridge and the hydraulic setting is directly proportional to the air setting at a ratio of 20:1 (hydraulic:air).
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- The pressure at port 3 determines the minimum valve setting and should not exceed 1000 psi (70 bar).
- The full adjustment range is 50 to 1500 psi (3,5 to 105 bar).
- Maximum air pressure should not exceed 150 psi (10,5 bar) due to the strength of the diaphragm.
- Maximum pressure differential, inlet to outlet, should not exceed 3000 psi (210 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- The air control feature allows explosion proof remote control.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity40 gpm
- Maximum Operating Pressure2000 psi
- Pilot Ratio20:1
- Control Pilot Flow15 - 20 in³/min.
- Maximum Air Pressure150 psi
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight1.30 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
I need a reducer on B. Can I connect the drain to A?
How big is a drop of hydraulic oil?
What do you mean by maximum differential?
Direct acting or pilot operated - what do I use?
Will your reducing/relieving valve relieve my pump to tank?
Can I back flow through a reducing valve from port 1 to port 2?
Highlights
Technical Tips
Technical Information