Model

PVFBLAN

Control
Adjustment Range
Seal Material
Material/Coating

Model: PVFB

Ventable, pilot-operated, pressure reducing/relieving valve

Cavity: T-22A | Capacity:

Model

PVFBLAN

Control
Adjustment Range
Seal Material
Material/Coating

Technical specifications

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    20 gpm
  • Maximum Operating Pressure
    5000 psi
  • Control Pilot Flow
    10 - 15 in³/min.
  • Factory Pressure Settings Established at
    blocked control port (dead headed)
  • Adjustment - No. of CW Turns from Min. to Max. setting
    5
  • Valve Hex Size
    1 1/8 in.
  • Valve Installation Torque
    45 - 50 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Model Weight
    .70 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • What are the tolerances on pressure settings for Sun's pressure control valves?
  • I need a reducer on B. Can I connect the drain to A?
  • How big is a drop of hydraulic oil?  
  • What do you mean by maximum differential?
  • Direct acting or pilot operated - what do I use?
  • Will your reducing/relieving valve relieve my pump to tank?
  • Can I back flow through a reducing valve from port 1 to port 2?
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure