Model

XRDCLANHL

Control
Adjustment Range
Seal Material
Range Letter(s) of Subordinate Cartridge
Port and Material Designation

Model: XRDC

Hot oil shuttle and relief assembly

Capacity:

Model

XRDCLANHL

Control
Adjustment Range
Seal Material
Range Letter(s) of Subordinate Cartridge
Port and Material Designation
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • 3, 3/S
      Ports 1 & 2: 3/4" Code 62; Port T: SAE 8; Gage Port: SAE 6; Mtg Holes: .375 - 16UNC x .62 DP;
    • 3/M, 3/T
      Ports 1 & 2: 3/4" Code 62; Port T: 3/8" BSPP; Gage Port: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
    • K, K/S
      Ports 1 & 2: SAE 10; Port T: SAE 8; Gage Port: SAE 6; Mtg Holes: .375 - 16UNC x .62 DP;
    • L, L/S
      Ports 1 & 2: SAE 12; Port T: SAE 8; Gage Port: SAE 6; Mtg Holes: .375 - 16UNC x .62 DP;
    • O, O/S
      Ports 1 & 2: 3/4" Code 61; Port T: SAE 8; Gage Port: SAE 6; Mtg Holes: .375 - 16UNC x .62 DP;
    • O/M, O/T
      Ports 1 & 2: 3/4" Code 61; Port T: 3/8" BSPP; Gage Port: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
    • V, V/S
      Ports 1 & 2: 1/2" BSPP; Port T: 3/8" BSPP; Gage Port: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;
    • W, W/S
      Ports 1 & 2: 3/4" BSPP; Port T: 3/8" BSPP; Gage Port: 1/4" BSPP; Mtg Holes: M10 x 1.5-6H x .62 DP;

    This valve assembly provides a flushing circuit for hydrostatic transmissions. The hot oil flushing circuit allows a discharge of oil from the low pressure side of the loop. The charge pump replaces the hot, dirty oil with cool, filtered oil. The hot oil discharge is often passed through the cases of the pump and the motor, flushing hot, dirty oil from them as well.

    • A unique feature of the hot oil shuttle is that the setting of the hot oil relief can be confirmed or adjusted when the transmission is in neutral.
    • The two ports marked 1 are common as are the two marked 2. Therefore the assembly can be teed off the loop rather than being plumbed into the loop.
    • When the transmission is in neutral the charge pressure is controlled by the charge pump relief. When the hot oil shuttle opens, some or all of the charge pump flow is redirected to the hot oil relief. The charge pump relief must be set higher than the hot oil relief to produce hot oil flow. The higher the differential pressure between the 2 reliefs, the higher the hot oil flow. The amount of hot oil flow is determined by the pressure vrs flow curves of the 2 reliefs and is difficult to quantify.
    • Hydraulic motors leak. Therefore a mechanical brake is recommended to positively lock any stopped live load.
    • Body Type
      Line mount
    • Interface
      None
    • Capacity
      10 gpm
    • Mounting Hole Quantity
      4

    Model CAD Files

    Click the link of the file format you want to download.

    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Direct acting or pilot operated - what do I use?
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
    • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.