Fixed setting, 1.5:1 pilot ratio, load reactive, load control valve
Cavity: T-17A | Capacity:
Technical specifications
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
- The maximum recommended load pressure for the K range is 2310 psi (159 bar). The cracking pressure for the K range will be 2880-3715 psi (199-256 bar).
- The maximum recommended load pressure for the L range is 3080 psi (212 bar). The cracking pressure for the L range will be 3880-4815 psi (268-332 bar).
- The maximum recommended load pressure for the M range is 3850 psi (265 bar). The cracking pressure for the M range will be 4880-5815 psi (336-401 bar).
- Note: The pressures listed under RANGE are approximate, mean values and should not be used for inspection purposes.
- Note: The percentage difference between the cracking and reseat values for the fixed and adjustable versions are identical. However, the cracking point for the adjustable control can be set via the adjustment mechanism to within +/- 15 psi (1 bar) or +/- 2.5% of setting (whichever is greater) of the specified value. In the case of the fixed version, the setting tolerance can only be maintained within a +/- 470-psi (32-bar) range. Thus for the 3000-psi (210-bar) fixed-setting model, with a rising pressure the valve will open below 3715 psi (256 bar) and with a falling pressure will reseat above 2310 psi (159 bar). For the 4000-psi (275-bar) fixed-setting model, with a rising pressure the valve will open below 4815 psi (332 bar) and with a falling pressure will reseat above 3080 psi (212 bar). For the 5000-psi (350-bar) fixed-setting model, with a rising pressure the valve will open below 5815 psi (401 bar) and with a falling pressure will reseat above 3850 psi (265 bar).
- Fixed-setting load control valves can be used to protect cylinder seals in outrigger circuits from damage due to thermal expansion, however, they probably should not be applied in circuits in which a matched valve setting may be required such as dual cylinder applications.
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- This valve is functionally a 3-port counterbalance valve. It seats as a poppet valve and modulates as a spool valve, offering the best of both valve types.
- These valves are capable of modulating over a broader range of flows than the pure poppet designs. The longer stroke allows us to incorporate a uni-directional damping device that smooths the opening and lets the valve close quickly.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Fixed-setting load control valves offer a shorter cartridge extension than the adjustable version.
- Sun load control and counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- This valve has positive seals between all ports.
- This valve has full relief capacity.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity60 gpm
- Maximum Operating Pressure5000 psi
- Pilot Ratio1.5:1
- Maximum Recommended Load PressureSee Technical Features
- Check Cracking Pressure25 psi
- Factory Pressure Settings Established at2 in³/min.
- Maximum Valve Leakage at Reseat5 drops/min.
- Reseat≥77% of setting
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
Why is turning the adjust screw for counterbalance valves opposite of most other valves?
What parts of the Sun cartridge valve are field serviceable?
You say your valves leak 5 drops/min. How can I keep my load from drifting?
How do I determine the setting of a counterbalance valve?
How do I know how much pilot pressure is required to lower a load with a counterbalance valve?
When should I use a vented counterbalance valve?
How does Sun test a counterbalance valve for leakage?
How do I decide which pilot ratio to select?
How big is a drop of hydraulic oil?
Why can't I use a counterbalance valve in a closed loop transmission circuit?
What do you mean by the setting of a counterbalance valve and what should it be?
I don't need pilot assist. Can I just block port 3?
Can I use an atmospherically vented counterbalance valve instead of the four-port version to save on plumbing?
Why is it that your valves have pilot ratios below 10:1, while other manufacturers start at 7:1 and go up?
Why can't I block the pilot vent port? That area is positively sealed, isn't it?
Should I replace the counterbalance valve if my cylinder is drifting or moving?
I have a pilot-to-open check on a large cylinder and the decompression is violent. Can I use a counterbalance instead?
How do I size a counterbalance valve?
Can I adjust a counterbalance valve in the field?
Why do you offer 2 check valve cracking pressures?
What happens to the counterbalance valve if I have backpressure in my system?
What do you mean by hysteresis when referring to a counterbalance valve?
- MBGB 1.5:1 pilot ratio, load reactive, load control valve
Highlights
Technical Tips
Technical Information