导压比 3:1, 标准型, LoadAdaptive™ 平衡阀
Cavity: T-11A | Capacity:
技术规格
- 平衡阀的设定值应该至少为负载压力值的1.3倍。
- 顺时针旋转调节将会减少设定,降低压力。
- 顺时针拧到底时设定压力小于500 psi (35 bar)。
- 2口的背压将会增加溢流值,增加值为(1+先导比)×压力值。注意:增加比例取决于先导压力,若没有先导压力,背压影响的增加比例将为10。
- 此阀在先导级没有主动密封,因此口3和口2将会有4 in³/min@1000 psi (65 ml/min.@70 bar)的泄漏量。这在主从回路以及阀-缸回路的泄漏测试中需要考虑进去。
- Sun的平衡阀可以被安装进执行器内部的安装孔,成为执行器的一部分,进而更加安全地保护回路。
- 有两种单向阀开启压力可选。在防止执行器气穴现象的时候,推荐使用4psi(0.3bar)的单向开启压力。
- 所有的3口平衡阀,负载控制阀,以及先导开启单向阀都结构上可以相互替换。(对同样的规格情况下,他们是相同流量路径相同孔型)
- 标准设定下,阀的复位压力值高于阀开启值的85%。当设定值小于标准设定值,复位压力值的百分比将相应变小。
- Sun浮动式的结构可以最大限度地减少由于过大的安装扭矩以及孔型加工的误差所造成的干涉现象。
- 插孔T-11A
- 系列1
- 通流能力15 gpm
- 先导比3:1
- 适应先导比See Performance Curves
- 最大设定时最大推荐负载压力3075 psi
- 最大设定4000 psi
- 回座时最大泄漏5 drops/min.
- 工厂默认的设定值2 in³/min.
- 调节 - 从最小设定到最大设定的逆时针圈数3.75
- 运行特性标准
- 复位>85% of setting
- 阀头部安装六角尺寸7/8 in.
- 阀安装扭矩30 - 35 lbf ft
- 调节螺栓的内六角尺寸5/32 in.
- 锁紧螺母六角尺寸9/16 in.
- 锁紧螺母力矩80 - 90 lbf in.
- 型号重量.55 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
Why is turning the adjust screw for counterbalance valves opposite of most other valves?
What parts of the Sun cartridge valve are field serviceable?
You say your valves leak 5 drops/min. How can I keep my load from drifting?
How do I determine the setting of a counterbalance valve?
How do I know how much pilot pressure is required to lower a load with a counterbalance valve?
When should I use a vented counterbalance valve?
How does Sun test a counterbalance valve for leakage?
How do I decide which pilot ratio to select?
How big is a drop of hydraulic oil?
Why can't I use a counterbalance valve in a closed loop transmission circuit?
What do you mean by the setting of a counterbalance valve and what should it be?
I don't need pilot assist. Can I just block port 3?
Can I use an atmospherically vented counterbalance valve instead of the four-port version to save on plumbing?
Why is it that your valves have pilot ratios below 10:1, while other manufacturers start at 7:1 and go up?
Why can't I block the pilot vent port? That area is positively sealed, isn't it?
Should I replace the counterbalance valve if my cylinder is drifting or moving?
I have a pilot-to-open check on a large cylinder and the decompression is violent. Can I use a counterbalance instead?
How do I size a counterbalance valve?
Can I adjust a counterbalance valve in the field?
Why do you offer 2 check valve cracking pressures?
What happens to the counterbalance valve if I have backpressure in my system?
What do you mean by hysteresis when referring to a counterbalance valve?