Loading...
平衡, 负载控制阀
Cavity: T-17A | Capacity:
See CAD Files tab below to request images.
技术规格
平衡型负载控制阀结合了平衡调节单元和反向单向阀两种功能。它允许油液从方向阀(口2)到负载口(口1)单向自由流通,同时先导油液将打开平衡调节单元以控制从口1到口2的液流,口3的先导压力决定流量的设定值。
- 这款阀没有溢流功能,甚至没有热泄功能。
- 最大泄漏量:I,K,M选项在低于开启压力200 psi (14 bar)时,泄漏量为5 drops/min (0,3 cc/min)。E,G选项在低于开启压力50 psi (3,5 bar)时,泄漏量为3 in³/min (50 cc/min)。
- E和G选项的阀不适用于0泄漏场合。
- 这款阀是与负载平衡,同时可以自我调节。通过先导压力控制流量。由于是动态密封,所以更为适用于出口流量控制,即1口接负载,2口接油箱。
- 2口的压力与3口的先导压力直接相互作用
- 这款阀和平衡阀结构上是可以相互替换的,但是并不能很好工作在它侧引流先导的液压缸应用上。低先导比阀可以使机器更稳定,而平衡负载控制型阀拥有极大的先导比。
- 采用单独控制源控制的先导口可以提供更平稳和稳定的负载控制。
- 所有的3口平衡阀,负载控制阀,以及先导开启单向阀都结构上可以相互替换。(对同样的规格情况下,他们是相同流量路径相同孔型)。
- Sun负载控制阀和平衡阀都可以之间安装于执行器外壳处,一次给执行器、回路更安全的保护。
- 此阀在所有口之间完全密封。
- Sun浮动式的结构可以最大限度地减少由于过大的安装扭矩以及孔型加工的误差所造成的干涉现象。
- 插孔T-17A
- 系列3
- 通流能力60 gpm
- 最大操作压力5000 psi
- 单向开启压力25 psi
- 回座时最大泄漏See Technical Features
- 阀头部安装六角尺寸1 1/4 in.
- 阀安装扭矩150 - 160 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Why is turning the adjust screw for counterbalance valves opposite of most other valves?
What parts of the Sun cartridge valve are field serviceable?
You say your valves leak 5 drops/min. How can I keep my load from drifting?
How do I determine the setting of a counterbalance valve?
How do I know how much pilot pressure is required to lower a load with a counterbalance valve?
When should I use a vented counterbalance valve?
How does Sun test a counterbalance valve for leakage?
How do I decide which pilot ratio to select?
How big is a drop of hydraulic oil?
Why can't I use a counterbalance valve in a closed loop transmission circuit?
What do you mean by the setting of a counterbalance valve and what should it be?
I don't need pilot assist. Can I just block port 3?
Can I use an atmospherically vented counterbalance valve instead of the four-port version to save on plumbing?
Why is it that your valves have pilot ratios below 10:1, while other manufacturers start at 7:1 and go up?
Why can't I block the pilot vent port? That area is positively sealed, isn't it?
Should I replace the counterbalance valve if my cylinder is drifting or moving?
I have a pilot-to-open check on a large cylinder and the decompression is violent. Can I use a counterbalance instead?
How do I size a counterbalance valve?
Can I adjust a counterbalance valve in the field?
Why do you offer 2 check valve cracking pressures?
What happens to the counterbalance valve if I have backpressure in my system?
What do you mean by hysteresis when referring to a counterbalance valve?
集锦
技术指导
技术信息