Loading...
2-vías , acción-directa electro-proporcional , compensado por presión control de caudal válvula con anti-retorno de caudal inverso
Cavity: T-16A | Capacity:
Especificaciones técnicas
- cavidadT-16A
- Series
- Capacity30 gpm
- Maximum Operating Pressure5000 psi
- Viscosity Range35 - 2000 SUS
- Response Time - Typical50 ms
- Switching Frequency3,600 max. cycles/hr
- Solenoid Tube Diameter.63 in.
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Model Weight1.20 lb
- Seal and nut kit - Coil
- Seal kit - Cartridge
- Seal kit - Cartridge
- Hysteresis (with dither)B-spool: 10%, C-spool: 9%
- Linearity (with dither)3%
- Repeatability (with dither)1.5%
- Recommended dither frequency100 Hz
- Deadband, nominal (as a percentage of input)B-spool: 35%, C-spool: 35%
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What happens if I block the control flow (priority) port?
I have a heat problem, will Sun's priority flow control help?
How big is a drop of hydraulic oil?
What is the pressure drop through a flow control?
What is the compensating pressure of Sun's flow controls?
How accurate are Sun's flow controls?
What happens if I block the bypass port on a priority flow control?
Aspectos destacados
Consejos técnicos
Información técnica