Loading...
Pilot-operated, normalmente cerrado, electro-proporcional estrangulación con anti-retorno de caudal inverso - (740 Series)
Cavity: T-18A | Capacity:
Especificaciones técnicas
- cavidadT-18A
- Series
- Capacity114 gpm
- Maximum Operating Pressure5000 psi
- Recommended dither frequency140 Hz
- Deadband, nominal (as a percentage of input)25%
- Maximum Valve Leakage at 110 SUS (24 cSt)20 drops/min.@5000 psi
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Model Weight2.36 lb
- Seal and nut kit - Coil
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What happens if I block the control flow (priority) port?
I have a heat problem, will Sun's priority flow control help?
How big is a drop of hydraulic oil?
What is the pressure drop through a flow control?
What is the compensating pressure of Sun's flow controls?
How accurate are Sun's flow controls?
What happens if I block the bypass port on a priority flow control?
Highlights
Consejos técnicos