Loading...
Divisor de caudal válvula
Cavity: T-31A | Capacity:
Especificaciones técnicas
- cavidadT-31A
- Series
- Capacity1.5 - 8 gpm
- Maximum Operating Pressure5000 psi
- Divisional Accuracy at Max Input Flow±3.5%
- Divisional Accuracy at Minimum Input Flow±6.5%
- Pressure Drop at Maximum Rated Input Flow250 psi
- Pressure Drop at Minimum Rated Input Flow30 psi
- Rated Input Flow with 33/67 Split1.2 - 6 gpm
- Rated Input Flow with 40/60 Split1.4 - 7 gpm
- Rated Input Flow with 50/50 Split1.5 - 8 gpm
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight.60 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
How big do my slip orifices have to be?
Why does Sun use 2 slip orifices?
Why am I getting a higher inaccuracy than Sun claims?
Most of the dividing-combining inaccuracies will average out, won't they?
Most of Sun's divider-combiners will do better than the published specs, won't they?
Can I synchronize two cylinders with Sun's divider-combiner?
How big is a drop of hydraulic oil?
What is the synchronizing feature?
How has Sun solved the hook breaking problem?
What is a priority flow divider?
Aspectos destacados
Consejos técnicos