Divisor de caudal válvula
Cavity: T-34A | Capacity:
Especificaciones técnicas
- cavidadT-34A
- Series
- Capacity12 - 60 gpm
- Maximum Operating Pressure5000 psi
- Divisional Accuracy at Max Input Flow±3.5%
- Divisional Accuracy at Minimum Input Flow±6.5%
- Pressure Drop at Maximum Rated Input Flow250 psi
- Pressure Drop at Minimum Rated Input Flow30 psi
- Rated Input Flow with 33/67 Split9 - 45 gpm
- Rated Input Flow with 40/60 Split10 - 50 gpm
- Rated Input Flow with 50/50 Split12 - 60 gpm
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Model Weight2.80 lb
- Seal kit - Cartridge