Modelo

FSFDXAN

Control
Flow Split
Seal Material
Material/Coating

Divisor de caudal válvula

Cavity: T-34A | Capacity:

Loading...

Modelo

FSFDXAN

Control
Flow Split
Seal Material
Material/Coating

Especificaciones técnicas

  • cavidad
    T-34A
  • Series
  • Capacity
    12 - 60 gpm
  • Maximum Operating Pressure
    5000 psi
  • Divisional Accuracy at Max Input Flow
    ±3.5%
  • Divisional Accuracy at Minimum Input Flow
    ±6.5%
  • Pressure Drop at Maximum Rated Input Flow
    250 psi
  • Pressure Drop at Minimum Rated Input Flow
    30 psi
  • Rated Input Flow with 33/67 Split
    9 - 45 gpm
  • Rated Input Flow with 40/60 Split
    10 - 50 gpm
  • Rated Input Flow with 50/50 Split
    12 - 60 gpm
  • Valve Hex Size
    1 5/8 in.
  • Valve Installation Torque
    350 - 375 lbf ft
  • Model Weight
    2.80 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big do my slip orifices have to be?
  • Why does Sun use 2 slip orifices?
  • Why am I getting a higher inaccuracy than Sun claims?
  • Most of the dividing-combining inaccuracies will average out, won't they?
  • Most of Sun's divider-combiners will do better than the published specs, won't they?
  • Can I synchronize two cylinders with Sun's divider-combiner?
  • How big is a drop of hydraulic oil?  
  • What is the synchronizing feature?
  • How has Sun solved the hook breaking problem?
  • What is a priority flow divider?