Modelo

HDDAXCN

X-Control
Control
Spool Configuration
Seal Material
bobina

Model: HDDA

2-vías , direccional, operada por solenoide disco válvula - después del anti-retorno

Cavity: T-11A | Capacity:

Modelo

HDDAXCN

X-Control
Control
Spool Configuration
Seal Material
bobina

Especificaciones técnicas

  • cavidad
    T-11A
  • Series
  • Capacity
    10 gpm
  • Maximum Operating Pressure
    5000 psi
  • Check Cracking Pressure
    30 psi
  • Manual Override Force Requirement
    5 lbs/1000 psi @ Port 1
  • Manual Override Stroke
    .10 in.
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    10 drops/min.@5000 psi
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Solenoid Tube Diameter
    .75 in.
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Seal and nut kit - Coil
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • 991225 Operación de giro momentáneo , activador manual juego de control, control T
  • 991226 Operación de retener / trabar, activador manual juego de control, control L
  • 991227 Operación doble de girar/bloquear, activador manual juego de control, control D