Loading...
Loading...

Modelo

K2Q

   
   
Modifier
Model: K2Q

Ninety degree with reverse flow check - reducing

Cavity: T-19A

Loading...

Modelo

K2Q

   
   
Modifier
Función
Function image

Especificaciones técnicas

  • Modifiers
    Ports
    • K2Q, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4
      Ports 1 & 2: 1 1/4" Code 61 ; Port 3: SAE 6; Gage Port: 1/4" NPTF;
    • K2Q/1A, /1B, /1F, /1G, /M, /T, /T3, /T4, /W, /W3, /W4, /Z
      Ports 1 & 2: 1 1/4" Code 61 ; Port 3: 1/4" BSPP; Gage Port: 1/4" BSPP;
    • cavidad
      T-19A
    • Body Type
      Line mount
    • Interface
      None
    • Body Features
      Ninety degree with reverse flow check - reducing
    • Check Cracking Pressure
      30 psi
    • Includes integral cartridge(s)
      Yes (see Included Components)
    • Mounting Hole Thread
      M10x1.5 - 6H (metric models)
    • Open Cavities
      1
    • Port Size
      1 1/4" Code 61
    • Mounting Hole Depth
      .38 in.
    • Mounting Hole Quantity
      2
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  

    Keep up with Sun