Loading...
Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico con indicador de posición
Cavity: T-17A | Capacity:
Especificaciones técnicas
- cavidadT-17A
- Series
- Capacity100 gpm
- Maximum Operating Pressure5000 psi
- Area Ratio, A3 to A11.8:1
- Area Ratio, A3 to A22.25:1
- Maximum Valve Leakage at 110 SUS (24 cSt)1 drops/min.
- Pilot Passage into Valve.06 in.
- Pilot Volume Displacement.25 in³
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Supply Voltage20-30 VDC
- Operating Temperature Range-25 to 80 °C
- Vibration≥ 50g, 0-500 impulses/sec
- Shock>50 g, 1ms
- Reverse Polarity ProtectionYes
- Maximum Output Load≤ 400 mA, Duty Ratio 100%
- Short Circuit ProtectionYes, Load Short Unlimited
- Turn On Time≤ 25 ms
- Hysteresis≤ .002 in.
- Thermal Shift - 0 to 80 °C ≤ ±.004 in.
- EMCDIN EN 61000-6-1/2/3/4
- conectorM12 X 1 (4) Pin
- Connector Environment RatingIP65
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- LOHO Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico
- 998100Z03 Serie 3, control Z herramienta de ensamblaje
Aspectos destacados
Consejos técnicos
Información técnica