Loading...
Loading...
Modelo
MWGBLHN
Venteado (a), proporción de pilotaje 1.5:1 , reactiva a la carga , control de carga válvula
Cavity: T-23A | Capacity:
Loading...
Modelo
MWGBLHN
Especificaciones técnicas
- cavidadT-23A
- Series
- Capacity60 gpm
- Maximum Operating Pressure5000 psi
- Pilot Ratio1.5:1
- Maximum Recommended Load PressureSee Technical Features
- Adjustment - No. of CCW Turns from Min. to Max. Setting9
- Check Cracking Pressure25 psi
- Factory Pressure Settings Established at2 in³/min.
- Maximum Valve Leakage at Reseat5 drops/min.
- Reseat≥77% of setting
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
Why is turning the adjust screw for counterbalance valves opposite of most other valves?
What parts of the Sun cartridge valve are field serviceable?
You say your valves leak 5 drops/min. How can I keep my load from drifting?
How do I determine the setting of a counterbalance valve?
How do I know how much pilot pressure is required to lower a load with a counterbalance valve?
When should I use a vented counterbalance valve?
How does Sun test a counterbalance valve for leakage?
How do I decide which pilot ratio to select?
How big is a drop of hydraulic oil?
Why can't I use a counterbalance valve in a closed loop transmission circuit?
What do you mean by the setting of a counterbalance valve and what should it be?
I don't need pilot assist. Can I just block port 3?
Can I use an atmospherically vented counterbalance valve instead of the four-port version to save on plumbing?
Why is it that your valves have pilot ratios below 10:1, while other manufacturers start at 7:1 and go up?
Why can't I block the pilot vent port? That area is positively sealed, isn't it?
Should I replace the counterbalance valve if my cylinder is drifting or moving?
I have a pilot-to-open check on a large cylinder and the decompression is violent. Can I use a counterbalance instead?
How do I size a counterbalance valve?
Can I adjust a counterbalance valve in the field?
Why do you offer 2 check valve cracking pressures?
What happens to the counterbalance valve if I have backpressure in my system?
What do you mean by hysteresis when referring to a counterbalance valve?
- MWGBX Ajuste fijo, venteado (a), proporción de pilotaje 1.5:1 , reactiva a la carga , control de carga válvula
Highlights
Consejos técnicos
Información técnica