Loading...
Pilot-operated, reductor/alivio de presión válvula
Cavity: T-19A | Capacity:
See CAD Files tab below to request images.
Especificaciones técnicas
- cavidadT-19A
- Series
- Capacity80 gpm
- Maximum Operating Pressure5000 psi
- Control Pilot Flow15 - 20 in³/min.
- Factory Pressure Settings Established atblocked control port (dead headed)
- Adjustment - No. of CW Turns from Min. to Max. setting5
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight3.10 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
I need a reducer on B. Can I connect the drain to A?
How big is a drop of hydraulic oil?
What do you mean by maximum differential?
Direct acting or pilot operated - what do I use?
Will your reducing/relieving valve relieve my pump to tank?
Can I back flow through a reducing valve from port 1 to port 2?
Highlights
Consejos técnicos
Información técnica