Model: RVCL
FLeX Series 2-stage, solenoid-operated ajustable alivio válvula , energize to vent
Cavity: T-10A | Capacity:
Especificaciones técnicas
- cavidadT-10A
- Series
- Capacity25 gpm
- Maximum Operating Pressure5000 psi
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)5 in³/min.@2000 psi
- Response Time - Typical50 ms
- Response Time - Typical (Relief)10 ms
- Adjustment - No. of CW Turns from Min. to Max. setting3.5
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Adjustment Screw Internal Hex Size1/8 in.
- Locknut Hex Size7/16 in.
- Locknut Torque45 - 55 lbf in.
- Model Weight.40 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- U.S. Patent #10,557,483
What parts of the Sun cartridge valve are field serviceable?
What is the difference between nominal and maximum flow capacity?
Do FLeX valves utilize a floating nose design?
Is the FLeX program available in QuickDesign SmartConnect?
What are the tolerances on pressure settings for Sun's pressure control valves?
Where would I use a kick-down relief?
Can I use a kick-down relief for my system relief?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
Highlights
Consejos técnicos
Información técnica