Loading...
FLeX Series 3-vías, acción-directa , electro-proporcional , desvió /restrictivo, prioritario control de caudal válvula
Cavity: T-17A | Capacity:
Especificaciones técnicas
- cavidadT-17A
- Series
- Capacity30 gpm
- Maximum Operating Pressure5000 psi
- Typical Valve Leakage at 110 SUS (24 cSt) from port 1 to port 3 at 1450 psi (100 bar)30 mL/min.
- Typical Valve Leakage at 110 SUS (24 cSt) from port 1 to port 3 at 5000 psi (350 bar)110 mL/min.
- Viscosity Range35 - 2000 SUS
- Response Time - Typical50 ms
- Switching Frequency3,600 max. cycles/hr
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Model Weight1.20 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- U.S. Patent #10,969,033
- Hysteresis (with dither)A-spool: 9%, B-spool: 7%, C-spool: 5%
- Linearity (with dither)A-spool: 2%, B-spool: 3%, C-spool 5%
- Repeatability (with dither)1.5%
- Recommended dither frequency100 Hz
- Deadband, nominal (as a percentage of input)25%
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
Does this FLeX series throttle control flow bidirectionally?
Can FLeX proportional valves be driven with an explosion proof coil?
What is the difference between nominal and maximum flow capacity?
Do FLeX valves utilize a floating nose design?
Is the FLeX program available in QuickDesign SmartConnect?
What happens if I block the control flow (priority) port?
I have a heat problem, will Sun's priority flow control help?
How big is a drop of hydraulic oil?
What is the pressure drop through a flow control?
What is the compensating pressure of Sun's flow controls?
How accurate are Sun's flow controls?
What happens if I block the bypass port on a priority flow control?
Highlights
Consejos técnicos
Información técnica