Loading...
De venteo, pilot-operated, pistón balanceado alivio válvula - antes del anti-retorno
Cavity: T-21A | Capacity:
Especificaciones técnicas
- cavidadT-21A
- Series
- Capacity10 gpm
- Maximum Operating Pressure5000 psi
- Check Cracking Pressure25 psi
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi
- Response Time - Typical10 ms
- Adjustment - No. of CW Turns from Min. to Max. setting5
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.35 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
Where would I use a kick-down relief?
Can I use a kick-down relief for my system relief?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- HVCA8 De venteo, pilot-operated, pistón balanceado alivio módulo principal con cavidad de control T-8A integral - antes del anti-retorno
Aspectos destacados
Consejos técnicos