De venteo, pilot-operated, pistón balanceado alivio módulo principal con cavidad de control T-8A integral - antes del anti-retorno
Cavity: T-21A | Capacity:
Especificaciones técnicas
- cavidadT-21A
- Series
- Capacity10 gpm
- Maximum Operating Pressure5000 psi
- Check Cracking Pressure25 psi
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi
- Pilot Control CavityT-8A
- Pilot Control Valve Installation Torque20 - 25 lbf ft
- Response Time - Typical10 ms
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
Where would I use a kick-down relief?
Can I use a kick-down relief for my system relief?
How big is a drop of hydraulic oil?
How do I get a kick-down relief to reset?
Direct acting or pilot operated - what do I use?